F226:Description:說明:
The level of the DC bus voltage will be monitored by the drive controller. If
the DC bus voltage falls below a minimal threshold, the drive
independently shuts down according to the set error reaction.
直流母線電壓的水平將由驅動控制器監控。如果直流母線電壓低于最小閾值根據設定的錯誤反應獨立關閉。
Cause:原因:
1. The power source has been interrupted without first switching off
the drive enable (RF).
電源在未首先關閉的情況下中斷驅動使能(RF)。
2. Disturbance in the power supply
電源干擾。
Remedy:排查思路:
For 1 Check the logic regarding the activation of the drive within
the connected control.
檢查內部驅動器激活的邏輯連接的控件。
For 2 Check the power supply.
檢查電源。
The error can be cleared by removing the control enable signal.
可以通過移除控制啟用信號來清除錯誤。